AquaSense-Oil

Single-path UV oil-in-water sensor with suspended-solids rejection, turbidity compensation, self-cleaning brush, and RS485 / Modbus output.

AquaSense-Oil uses a single UV light path that automatically rejects interference from suspended solids, delivering more stable and reliable oil-in-water readings without reagents. Built-in turbidity compensation and a self-cleaning brush keep the sensor accurate during long-term, unattended deployments.

AquaSense-Oil UV oil-in-water sensor

Single UV Light Path

Auto-rejects suspended-solids interference for stable readings.

Reagent-Free

No chemicals or consumables — economical and environmentally friendly.

Continuous Monitoring

Designed for unattended in-line and in-situ deployments.

Self-Cleaning Brush

Built-in wiper keeps optical window clean for long maintenance intervals.

No Reagents

Reagent-free optical measurement keeps the deployment clean and low-maintenance.

Auto-Cleaning Option

Optional self-cleaning wiper resists biofouling for long-duration service.

Digital Output

RS485 with Modbus RTU protocol for easy logger and PLC integration.

Temperature Compensation

Built-in temperature sensor with automatic compensation.

Continuous Monitoring

Designed for unattended in-line and in-situ deployments.

Stable & Drift-Resistant

Tight optical path and software algorithms minimise long-term drift.

AquaSense-Oil Overview

AquaSense-Oil is a UV fluorescence oil-in-water sensor designed for leak detection, environmental compliance, and continuous online monitoring. The single UV light path is engineered to automatically reject interference from suspended solids, delivering more stable readings than dual-path designs — without the need for reagents or consumables.

Built-in turbidity compensation and a self-cleaning brush keep the optical window clean for long-term unattended deployments, so the sensor stays accurate even in challenging effluent and harbour applications. The RS485 / Modbus RTU interface integrates directly into AquaSense-Multi sondes and shore- and buoy-based telemetry systems.

AquaSense-Oil Product Image

AquaSense-Oil UV oil-in-water sensor
Primary view of the AquaSense-Oil uv oil-in-water fluorescence sensor.

AquaSense-Oil Key Specifications

Parameter
Value
Measurement Principle
Single-path UV fluorescence
Auto-rejects SS interference
Oil-in-Water Range
0 to 50 mg/L
Selectable sub-ranges
Resolution
0.01 mg/L
Output resolution
Accuracy
±5% of reading
After calibration
Reagents
None
Reagent-free
Turbidity Compensation
Automatic
On-board algorithm
Cleaning
Self-cleaning brush
Anti-biofouling
Temperature Range
0 to 50 °C
Water temperature
Output
RS485, Modbus RTU
Default digital interface
Power Supply
DC 9-24 V
Low-power operation
Ingress Protection
IP68
Submersible body
Cable Length
10 m standard, customisable
Submersible cable
View Full Specifications

AquaSense-Oil Supported Parameters

Measured Parameters

Oil-in-Water (mg/L) Water Temperature

Output Options

RS485 Modbus RTU

Power Options

DC 9-24 V

Environmental

0-50 °C IP68 Submersible Self-cleaning

AquaSense-Oil Resources and Downloads

AquaSense-Oil Accessories

Calibration Solutions

Standard buffer and reference solutions for routine calibration.

Cable & Junction Box

Submersible cabling and weatherproof junction options for field wiring.

Mounting Hardware

Probe guards, flow cells, and pole or buoy mounting adapters.

AquaSense-Oil Support and Deployment Guidance

Wiring and protocol assistance for RS485 / Modbus RTU integration.

Integration support for sondes, buoys, fixed stations, and process panels.

Calibration, field-verification, and long-term maintenance planning.

Application support for freshwater, brackish, marine, and industrial deployments.

AquaSense-Oil Frequently Asked Questions

What is AquaSense-Oil?

AquaSense-Oil is single-path UV oil-in-water sensor with suspended-solids rejection, turbidity compensation, self-cleaning brush, and RS485 / Modbus output. AquaSense-Oil uses a single UV light path that automatically rejects interference from suspended solids, delivering more stable and reliable oil-in-water readings without reagents. Built-in turbidity compensation and a self-cleaning brush keep the sensor accurate during long-term, unattended deployments.

What parameters does AquaSense-Oil support?

AquaSense-Oil supports Oil-in-Water (mg/L), Water Temperature, RS485, Modbus RTU, DC 9-24 V, 0-50 °C, IP68, Submersible, and other configured parameters.

Where is AquaSense-Oil typically used?

AquaSense-Oil is typically used for Surface water, groundwater, and reservoir monitoring, Aquaculture farms and hatcheries, Municipal water supply and wastewater treatment, Environmental compliance and pollution control.

What systems work with AquaSense-Oil?

AquaSense-Oil can be configured with AquaSense-Multi Multi-Parameter Sonde, OceanStations, CoreLink Telemetry and related Zenocean monitoring platforms or telemetry systems.

What support is available for AquaSense-Oil?

Zenocean provides configuration, integration, deployment and maintenance guidance for AquaSense-Oil projects.

Ready to add reliable water-quality data?

Let's match the right probe, calibration plan, and integration to your monitoring program.

Get in Touch

Trusted by Experts

Used by researchers, engineers, and operators worldwide.

Built for Water

Designed for reliable freshwater, brackish, and marine service.

End-to-End Solutions

Sensors, platforms, systems, and software working together.

Global Support

Local teams and partners ready to help deploy and scale.